DVP28SV11T2

DVP28SV11T2 Delta PLC

Delta Programmable Logic Controllers, SV2 Series

SV2 Series Information

  • High‑speed pulse output: 4 sets of 200kHz pulse output
  • Supports max. 4 hardware 200kHz high‑speed counters
  • Increases many motion control instructions to meet the applications that require high‑speed and high‑precision positioning
  • Offers linear / arc interpolation motion control
  • Provides up to 16 external interrupt pointers

DVP28SV11T2 PRICE

Common characteristics

  • Adopts 32-bit CPU
  • Clip-on extension modules- general (right side)
  • Plug-in terminals for ease of wiring and maintenance
  • Compact dimensions (H) 90 mm x (D) 60 mm DIN rail mounting
  • Built-in high speed counters up to 100 – 200 kHz (model dependant)
  • Dual communication ports RS232 and RS485 MODBUS ASCII/RTU compatible
  • Program language: (IL) instruction list, (LD) ladder diagram, (SFC) sequential function chart

SV2 series high performance PLC

SV2 series high-end PLC providing larger program capacities and data registers for more demanding, complex applications. Increases many motion control instructions to meet high-speed applications, high-precision positioning control for labelling, packaging and printing machines.

Specifications

Item Number: DVP28SV11T2
Brand: Delta Products
Item Category:Programmable Logic Controllers
Series: SV2
Number of Inputs & Type: 16 – Digital
Number of Outputs & Type: 12 – Transistor
Expandable: Up to 480 I/O Points
Display Type: I/O Indicator LEDs
Approvals: UL;CE
H x W x D: 3.54 in x 2.36 in x 2.09 in

AMS ES PLC

  • DC24V
  • High-speed input: 2 channel 100kHZ; 6 channel 10kHz
  • Single phase input 8 points: AB phase input 4 groups
  • High-speed comparison interrupt: 8 points
  • Communication port 1RS232, 2RS485
  • 8 expansion modules can be connected, support S-curve acceleration and deceleration function, support inverter control commands

Check Price

ModelPLC16ESR/TPLC24ESR/TPLC32ESR/TPLC40ESR/TPLC60ESR/T
Input816162436
Output88161624
L105126145165225
L197115137157217

Parameter

Power supply voltage24VDC/100-240VAC(-15%-10%)
Connection methodDrop-off European terminal block (distance between endpoints: 5MM)
Operation specificationsWhen the power supply slowly rises to 95~100VAC, the PLC starts to move, and when the power supply drops slowly to 70VAC, the PLC stops its action. The power supply will continue to run within 10MS of instantaneous power failure.
Power fuse capacity2A/250VAC
Power consumption30VA
DC24V current output*1500MA
Power protectionDC24V output with short circuit protection
Surge voltage tolerance1,500VAC (PRIMARY-SECONDARY), 1,500VAC(PRIMARY-PE)
500VAC(SECONDARY-PE)
Insulation resistanceAbove 5Q (500VDC between all output/input points and ground)
Interfere with immunityESD(IEC 61131-2JEC61000-4-2):8KV AIR DISCHARGE
EFT (IEC 61131-2, 61000-4-4): POWER LINE: 2KV, DIGITAL /0: 1KV,
ANALOG& COMMUNICATION/O: 1KV
RS (IEC 61131-2,LEC 61000-4-3): 26MHZ-1GHZ,10V/M
GroundedThe wire diameter of the grounding wiring shall not be less than the wire diameter of the power terminal L and N
(When multiple PLCs are used at the same time, be sure to ground at a single point)
Operating/storage environmentOperation 0℃-55℃ (temperature), 5-95% (humidity) Pollution degree 2
Storage: 25℃-70℃ (temperature), 5-95% (temperature)

Analog module input/output (number of channels * resolution) configuration

ModelDVP04AD-E2DVP04DA-E2DVP06XA-E2DVP02DA-E2DVP04TC-E2DVP04PT-E2
InputAD1-4(4CHx14-bit)AD1-4(4CHx14-bit)CH1-4(4CHx16-bit)CH1-4(4CHx16-bit)
OutputDA1-4(4CHx14-bit)DA1-2(2CHx14-bit)DA1-2(2CHx14-bit)
elementrang
X external input relayX0-377, 256 points, octal code (*4)
Y external output relayY0-Y377, 256 points, octal code (*4)
M auxiliary relay for general useM0~M511,512 points (*1) M768~M999, 232 points (*1)
M2000-M2047, 48 points (*1)
M auxiliary relay power failure retention
use
M512~M767, 256 points (*2)
M2048-M4095, 2,048 points (*2)
M auxiliary relay for special useM1000~M1999,1,000points (partially maintained after power failure)
T Timer 100ms (M1028=ON,T64~T126为10ms)T0~T126,127 points(*1)
T128-T183,56 points(*1)
T184~T199 subroutines with 16 points (*1)
T250~T255],6-point accumulation type (*1)
T Timer 10ms(M1038=ON,T200-245为1ms)T200-239,40points(*1)
【T240~T245】,6 points Cumulative(*1)
T Timer 1msT127,1 points (1)
【T246-T249】,4 points Cumulative(*1)
C counter 16-bit upper numberC0-111,112 points(*1)
C112-C127,16 points (*2)
C128-C199,72 points(*1)
C counter 32-bit up/down numberC200-C223,24 points(*1)
C224-C232,8 points(*2)
C counter 32-bit high-speed counterC235-C244,1 phase 1 input,,10 points (*2)
C245-C250,1 phase 2 input,,6 points (*2)
C233,C234,C251-C254,2 phase 2 input,,7 points(*2)
S step point initial step pointS0-S9,10 points(*2)
S step point for home returnS10-S19,10 points(used with ST command)(*2)
S Step point For power failure retentiveS20-S127,108 points(*2)
S step point Generally useS128-S911,784 points(*1)
S Step point for alarmS912-S1023,112 points(*2)
T timer current valueT0-255,16-bit timer256 points
C Counter current valueC0~C199,16-bit counter 200 points
C200-C254,32-bit counter 55 points
D data register generally useD0-D407,408 points,(*1)
D600-D999,400 points(*1)
D3920~D9899,5,980 points(*1)
D Data register for power failure retentionD408-D599,192 points(*2)
D2000-D3919,1,920 points(*2)
D Data register For special registerD1000-D1999,1,000 points (Some are maintained after power failure)
D Data register for special modulesD9900-D9999,100 points(*1)(*5)
D Data register for indirect designationE0-e7, f0-f7.16 points(*1)
N Master Reusen0-n7,8 points
P CJ, CALL instructionP0-P255,256 points
I interrupt External interrupt insertionI00口(X0),I10口(X1)I20口(X2)
I30口(X3),I40口(X4),I50口(X5),
I60口(X6),I70口(X7),8 points
(口=1,trigger on rising edge,口=0,trigger on falling edge)
I interrupt Timed interrupt insertionI6口口,I7口口,(口口-05~99ms),2 points
I interrupt High-speed counting reaches interrupt insertionI010、I020、I030、I040、I050、I060、I070、I080,8 points
I interrupt communication reception interrupt insertionI40(COM1)、I150(COM2)、I60(COM3)(*3),3 points
Constant K decimalK-32,768-K32,767(116-bit operation)
K-2,147,483,648~K2,147,483,647(32-bit operation)
Constant H hexadecimalH0000- HFFFF(16-bit operation)
H00000000 -HFFFFFFFF-(32-bit operation)
*1 Non-latched area, cannot be changed
*2 The latched area cannot be changed
*3 COM1 is the built-in RS-232 communication port, COM2 and COM3 are the built-in RS-485 communication ports
*4 When the number of digital input expansion X points is extended to 256 points, the output Y can only use 16 points. On the contrary, when the output Y points are extended to 256 points, the input X can only use 16 points.
*5 This area will be valid only when the host is connected to an analog module, and each connected analog module will occupy 10 points

Power-off hold action

Memory typePower OFF→ ONSTOP→RUNRUNSTOPM1031 non-maintained areas are all clearedM1032 power failure retention area is all clearedFactory setting value
Non-power failure retentionClearNo changeWhen M1033 is OFF, clear
When M1033 ON, no change
ClearNo change0
power failure retentionNo changeNo changeNo changeNo changeClear0
Special M, Special D indirectly designated registerInitial value settingNo changeNo changeNo changeNo changeInitial value setting

Software

DELTA_IA-PLC_WPL_V2.50_SW_20201119

JL1N PLC

fx1n plc
  • This programmable logic controller uses industrial-grade 32-bit MCU with strong anti-interference and faster speed.
  • The PLC board directly uses GX programming software for ladder diagram, written to the PLC directly, can monitor online.
  • It supports super encryption, as long as input password under PLC state, there is no read function.
  • Stable and reliable performance, build-in watchdog timer circuit, effectively ensures module long time work.
  • Widely used in all kinds of industrial automatic control, such as metallurgy, chemical, plastics, textile, food, packaging, printing, building materials, carpentry, central air conditioning, environmental protection equipment and industrial single process control equipment in industrial assembly line, various kinds of machine tools.

Check Price

Basic Sequential Control Commands

LD, LDI, OUT, AND, ANI, OR, ORI, LDP, LDF, ANDP, ANDF,
ORP, ORF, ORB, ANB, MPS, MRD, MPP, MC, MCR, INV, PLS,
PLF, SET, RST, OUT, RST, NOP, END , CALL, CJ , FEND
SRET, STL, RET
Data Processing Command:
ZRST, DECO, ENCO, SUM, BON, MEAN, SQR, SWAP
High Speed Processing Command:
SPD, PLSY, PWM, PLSR, HSCS, HSCR
Positioning Command:
PLSV, DRVI, DRVA
Convenient Command:
ALT, INCD
Contact Comparison Command:
LD=, LD>, LD<, LD<>, LD≤, LD≥,AND=, AND>, AND<, AND<>, AND≤, AND≥, OR=, OR>, OR<, OR<>, OR≤, 0R≥
All commands support 32-bit commands and trigger commands

*Input high speed pulse C235,C238,C251,C253 function compatible with FX1N.
*Y0 Y1 can send maximum 10K pulse, function compatible with FX1N.

When using WORK2 and GX, the baud rate must be set to 9.6K, otherwise communication will not be possible

Tips
Some customers respond that downloading programs is slow. The length of the download program is 8000 steps by default. Actually, most of the programs written by customers will not exceed 2000 steps, so you can set it in the software in GX or WORK2. Download speed increased by 4 times
How to set
After clicking the + sign in front of the parameter in the program data list, the PLC parameter will appear, and then double-clicking the PLC parameter, the parameter setting interface will appear. In the parameter setting interface, set the memory capacity from 8000 to 2000.

FX1N PLC series has 2 independent 232 serial ports (1,232 level 9pin port (2:TXD 3:RXD 5:GND)2, TTL level 4pin port (1:GXD 2:TXD 3:RXD 4:5V) ), both ports are programmable and connected to the touch screen. When programming, the 9pin port selects the USB-232 line;
The 4pin port uses a USB-TTL cable. When connecting the touch screen, the 232 level 9pin port is directly connected to the touch screen with a DB9 male-to-female cable (actually only 3 wires are used, 2-2, 3-3, 5-5). The TTL level 4pin port needs to use our company’s TTL to 232 conversion board to convert to 232 level before it can be connected to the touch screen.

Encryption

1,After powering on, click online-remote operation
2,Stop PLC [RUN changed to STOP]
3,Click to execute, the running light [RUN] on the circuit board will go out after execution, enter the keyword
4,New login keyword-input 11111111 and confirm. After encryption, only upload Program

Text Example

GX-Developer-8.50C-E error

Because the pathname of the installer folder is too long installation processing is discontinued.Please move the installer folder to the place which the pathname becomes 100 or less letters and execite setup.exe once again.

Slove

such as D:/asdfadsfdsafdsafsad/gx-develp/. is folder is too long, D:/gx-develp is short.